Industrial Reverse Osmosis Plant Manufacturer in Pune
- Techno Multi Services Engineering Guarantees:
- Up to 99.2% Dissolved Salt (TDS) Rejection (Permeate TDS < 30 ppm)
- High Recovery Efficiency: 75% to 85% Water Recovery with Energy Recovery Skids
- Custom Skid Capacities: 500 LPH, 2,000 LPH, 10,000 LPH to 100 m³/hr+
- Rapid On-Site Technical Support in Chakan, Bhosari, Ranjangaon & Talegaon
24/7 On-Site Industrial RO Repair, Membrane Descaling & CIP Services
- Pump Repair - Overhauling and mechanical seal replacement.
- CIP Descaling - Chemical cleaning to restore membrane performance.
- Membrane Replacement - SDI testing and genuine membrane replacement.
- Dosing Calibration - Repair and calibration of chemical dosing pumps.
Compliance & Operational Risks
Battling High Water Salinity, Premature Membrane Scaling & Crippling Energy Costs?
Rapid Mineral Scaling & Premature Membrane Death
Calcium sulfate, calcium carbonate, and colloidal silica precipitate on thin-film composite (TFC) membrane surfaces, choking flux and permanently damaging membrane sheets within months.
Frequent CIP Acid Downtime & High Energy Bills
Scaling causes feed pump discharge pressures to soar from 12 bar to over 18 bar. Industrial facilities experience huge electrical spikes, recurring CIP chemical cleaning shutdowns.
Costly Boiler Tube Blowdown & Cooling Tower Corrosion
Uncontrolled manual chemical dosing leads to wasted reagents, massive hazardous sludge generation, high CHWTSDF disposal fees, and recurrent pump failures.
The Engineering Advantage
The Techno Multi Services RO Engineering Advantage
We integrate premium high-rejection Thin-Film Polyamide membranes (DuPont FilmTec, Hydranautics, Toray), SS316 multi-stage high-pressure pumps (Grundfos / CNP), automated antiscalant/SMBS dosing skids, and built-in Clean-In-Place (CIP) systems.
From compact packaged 1,000 LPH skids to massive 100 m³/hr multi-stage utility RO plants, Techno Multi Services delivers turnkey reliability with guaranteed permeate conductivity.
- Turnkey single-source accountability: from bench-scale jar testing to full commissioning, MPCB adequacy certification, and long-term AMC support.
Multi-Barrier Technologies
Our Core Reverse Osmosis Technologies & Membrane Configurations
Brackish Water Reverse Osmosis (BWRO Systems)
Engineered for raw borewell and municipal water with TDS ranging from 1,000 to 5,000 ppm. Operating with spiral-wound polyamide elements at 12–16 bar, our BWRO plants consistently produce permeate with TDS < 50 ppm, ideal for industrial process loops and drinking water.
Double-Pass (Two-Pass) RO for Ultra-Pure Water
In high-purity sectors like pharmaceuticals and electronics, permeate from the first pass is routed directly as feed into a second RO stage. This strips trace conductivity down to < 1.0 µS/cm and eliminates endotoxins, delivering consistent USP Purified Water (PW) grade feed.
High-Pressure RO for Effluent & ZLD Recycling
Specially designed rugged skids utilizing high-pressure seawater/disc-tube membrane elements operating at up to 70–85 bar. Systems concentrate industrial wastewater TDS from 15,000 ppm up to 70,000+ ppm, dramatically reducing the volume and thermal energy cost of downstream ZLD.
High-Recovery Multi-Stage & Tapered Array RO
To maximize scarce water conservation, we engineer 2-stage and 3-stage tapered pressure vessel arrays (e.g., 4:2:1 vessel ratio) paired with concentrate re-circulation and inter-stage booster pumps, achieving 80% to 85% water recovery without mineral scaling.
Integrated Clean-In-Place & Sanitization Skids
Dedicated chemical wash tanks, SS316 transfer pumps, and 5-micron cartridge pre-filters enabling automated low-pH (inorganic scale removal) and high-pH (organic/biofilm removal) cleanings to restore 95%+ membrane flux without physical dismantling.
Advanced Instrumentation & Fail-Safe Controls
Digital conductivity/TDS controllers, online flow transmitters, digital pressure switches, low-pressure/high-pressure pump interlocks, and PLC automation with remote SCADA integration.
Design Parameters
Engineering Specifications & Feed Water vs Guaranteed Permeate Standards
Parameter / Metric |
Raw Feed Water Standard |
TMS Guaranteed Permeate Standard |
Application Benefit |
|---|---|---|---|
|
Total Dissolved Solids (TDS)
|
1,000 – 6,000 mg/L
|
< 25 – 50 mg/L (99%+ Rejection)
|
Prevents Boiler/Chiller Scale
|
|
Electrical Conductivity
|
1,500 – 9,000 µS/cm
|
< 40 – 80 µS/cm (< 2 µS in Two-Pass)
|
High Process Purity
|
|
Reactive Silica (SiO₂)
|
15 – 80 mg/L |
98% Rejection)
|
Zero Boiler Tube Scaling
|
|
Total Hardness (as CaCO₃)
|
300 – 1,500 mg/L
|
NIL / < 1.0 mg/L
|
Eliminates Water Softening
|
|
Chlorides & Sulfates |
300 – 2,500 mg/L
|
< 10 mg/L
|
Stops Stress Corrosion
|
|
Recovery Efficiency
|
N/A |
75% – 85% (Optimized Tapered Arrays)
|
Reduces Water Wastage
|
Available Skid Capacities
500 LPH, 1,000 LPH, 2,000 LPH, 5,000 LPH, 10,000 LPH, 25,000 LPH to 100 m³/hr+
High-Pressure Pump Specs
Vertical Multistage SS304/SS316 (Grundfos / CNP / CRI) with VFD speed control
Membrane Brand & Housing
DuPont FilmTec / Hydranautics / Toray; FRP Code-line pressure vessels (300 to 1,000 PSI)
Turnkey Execution
Our 6-Step Turnkey RO Project Delivery Workflow
01. Phase
Raw Water Chemical Profile & Scaling Indices
Comprehensive laboratory testing for TDS, SDI, Silica, Barium, Strontium, and LSI/SDSI scaling indices.
02. Phase
Computer Aided Membrane Simulation
Hydraulic modeling to determine precise membrane element count, pressure vessel configuration, flux rate (GFD), and antiscalant dosage
03. Phase
Precision Structural Skid Fabrication
Heavy-duty structural SS304 or epoxy-coated skid frame fabrication, precision vibration isolation, and manifold assembly.
04. Phase
High-Pressure Piping & Instrumentation Assembly
Installation of schedule-40 SS316 high-pressure piping, low-pressure CPVC piping, rotameters, and digital conductivity sensors.
05. Phase
Wet Commissioning, Salt Rejection & Flux Tuning
System flushing, membrane stabilization wet run, flow balancing, recovery optimization, and automatic fail-safe testing.
06. Phase
Performance Validation & Handover
Verification of permeate conductivity, comprehensive O&M manual delivery, and on-site operator training on CIP procedures.
Sector Applications
Sector Specific RO Applications Across Pune & Maharashtra
Chakan MIDC (Phases 1-4), Talegaon, Bhosari.
Automobile OEMs & Tier-1 Ancillaries
Low-conductivity permeate for CED paint shops, phosphating rinses, component washing machines, and cooling towers.
Kurkumbh, Chakan, Paithan, Waluj
Pharmaceutical & Bulk Drug Formulations
Two-pass sanitary SS316L RO skids providing USP Purified Water feed for formulation, packaging lines, and boiler feed.
Hinjewadi, Kharadi, Magarpatta.
Commercial IT Campuses & Data Centers
High-efficiency RO plants delivering demineralized water for HVAC cooling tower make-up and data center evaporative cooling.
Kurkumbh MIDC, Ranjangaon, Roha, Taloja.
Chemical Synthesis & Agrochemical Plants
High-pressure RO skids for process wastewater concentration, reducing volume prior to MEE evaporators in ZLD circuits.
Baramati, Shirwal, Hadapsar, Pune.
Food, Dairy & Beverage Processing
FSSAI-compliant RO purification systems for drinking water bottling, syrup preparation, boiler steam, and crate washing.
Daund, Baramati, Shirwal, Ranjangaon.
Thermal Power & Industrial Captive Boilers
Demineralized feed pre-treatment to ensure zero boiler blowdown loss, scale-free boiler tubes, and maximum thermal fuel efficiency.
Commercial Engagement
Comprehensive RO Services: Turnkey EPC, Retrofitting & AMC
Turnkey RO Plant EPC Supply
Complete design, skid fabrication, pressure vessel loading, and turnkey commissioning from 500 LPH to 100 m³/hr+.
RO Membrane Replacement
Membrane inspection, replacement, and skid re-piping to improve recovery from 60% to 80%.
Comprehensive RO AMC
AMC services covering CIP cleaning, pump maintenance, chemical supply, and SDI monitoring across Pune.
Frequently Asked Questions
In a Single-Pass RO, feed water passes through membranes once, producing permeate with 98-99% TDS reduction (e.g., 2,000 ppm reduced to 30 ppm). In a Double-Pass RO, the permeate from the first pass becomes the feed for a second pass, stripping remaining minerals down to conductivity < 1-2 µS/cm (ideal for pharma and high-pressure boilers).